-rw-r--r--sys/dev/bge/if_bge.c23
1 files changed, 19 insertions, 4 deletions
diff --git a/sys/dev/bge/if_bge.c b/sys/dev/bge/if_bge.c
index 24bc04f..7012cdf 100644
--- a/sys/dev/bge/if_bge.c
+++ b/sys/dev/bge/if_bge.c
@@ -2045,6 +2045,7 @@ bge_intr(xsc)
struct bge_softc *sc;
struct ifnet *ifp;
u_int32_t statusword;
+ u_int32_t status;
sc = xsc;
ifp = &sc->arpcom.ac_if;
@@ -2073,7 +2074,6 @@ bge_intr(xsc)
*/
if (sc->bge_asicrev == BGE_ASICREV_BCM5700) {
- u_int32_t status;
status = CSR_READ_4(sc, BGE_MAC_STS);
if (status & BGE_MACSTAT_MI_INTERRUPT) {
@@ -2089,9 +2089,24 @@ bge_intr(xsc)
}
} else {
if (statusword & BGE_STATFLAG_LINKSTATE_CHANGED) {
- sc->bge_link = 0;
- untimeout(bge_tick, sc, sc->bge_stat_ch);
- bge_tick(sc);
+ /*
+ * Sometimes PCS encoding errors are detected in
+ * TBI mode (on fiber NICs), and for some reason
+ * the chip will signal them as link changes.
+ * If we get a link change event, but the 'PCS
+ * encoding error' bit in the MAC status register
+ * is set, don't bother doing a link check.
+ * This avoids spurious "gigabit link up" messages
+ * that sometimes appear on fiber NICs during
+ * periods of heavy traffic. (There should be no
+ * effect on copper NICs.)
+ */
+ status = CSR_READ_4(sc, BGE_MAC_STS);
+ if (!(status & BGE_MACSTAT_PORT_DECODE_ERROR)) {
+ sc->bge_link = 0;
+ untimeout(bge_tick, sc, sc->bge_stat_ch);
+ bge_tick(sc);
+ }
/* Clear the interrupt */
CSR_WRITE_4(sc, BGE_MAC_STS, BGE_MACSTAT_SYNC_CHANGED|
BGE_MACSTAT_CFG_CHANGED);
OpenPOWER on IntegriCloud