diff options
author | mav <mav@FreeBSD.org> | 2013-01-12 21:51:49 +0000 |
---|---|---|
committer | mav <mav@FreeBSD.org> | 2013-01-12 21:51:49 +0000 |
commit | 8de7e6376516d3e9b28116150334515cc78459ed (patch) | |
tree | 7d9026788131fe96a168fccbd639a83941d68679 /sys/geom/raid | |
parent | c3acd922ed43d64e4ae6f4201d42e542a466707a (diff) | |
download | FreeBSD-src-8de7e6376516d3e9b28116150334515cc78459ed.zip FreeBSD-src-8de7e6376516d3e9b28116150334515cc78459ed.tar.gz |
Windows handles INIT and VERIFY as array-wide and it doesn't specify which
disks should be rebuilt. Our rebuild code is same time disk-centric. To
handle this situation properly check all disks for RBLD flags, and if no
disk specified try rebuild/resync all of them except newly inserted.
Diffstat (limited to 'sys/geom/raid')
-rw-r--r-- | sys/geom/raid/md_intel.c | 17 |
1 files changed, 15 insertions, 2 deletions
diff --git a/sys/geom/raid/md_intel.c b/sys/geom/raid/md_intel.c index fc7154b..4a6fdf6 100644 --- a/sys/geom/raid/md_intel.c +++ b/sys/geom/raid/md_intel.c @@ -774,7 +774,7 @@ g_raid_md_intel_start_disk(struct g_raid_disk *disk) struct intel_raid_conf *meta; struct intel_raid_vol *mvol; struct intel_raid_map *mmap0, *mmap1; - int disk_pos, resurrection = 0; + int disk_pos, resurrection = 0, migr_global, i; sc = disk->d_softc; md = sc->sc_md; @@ -903,6 +903,13 @@ nofit: else mmap1 = mmap0; + migr_global = 1; + for (i = 0; i < mmap0->total_disks; i++) { + if ((mmap0->disk_idx[i] & INTEL_DI_RBLD) == 0 && + (mmap1->disk_idx[i] & INTEL_DI_RBLD) != 0) + migr_global = 0; + } + if (resurrection) { /* Stale disk, almost same as new. */ g_raid_change_subdisk_state(sd, @@ -953,6 +960,11 @@ nofit: sd->sd_volume->v_strip_size * mmap0->total_domains; } + } else if (mvol->migr_type == INTEL_MT_INIT && + migr_global) { + /* Freshly created uninitialized volume. */ + g_raid_change_subdisk_state(sd, + G_RAID_SUBDISK_S_UNINITIALIZED); } else if (mvol->dirty && (!pv->pv_cng || pv->pv_cng_master_disk != disk_pos)) { /* Dirty volume (unclean shutdown). */ @@ -969,7 +981,8 @@ nofit: /* Freshly inserted disk. */ g_raid_change_subdisk_state(sd, G_RAID_SUBDISK_S_NEW); - } else if (mmap1->disk_idx[sd->sd_pos] & INTEL_DI_RBLD) { + } else if ((mmap1->disk_idx[sd->sd_pos] & INTEL_DI_RBLD) || + migr_global) { /* Resyncing disk. */ g_raid_change_subdisk_state(sd, G_RAID_SUBDISK_S_RESYNC); |