summaryrefslogtreecommitdiffstats
path: root/sys/dev/hme
diff options
context:
space:
mode:
authormarius <marius@FreeBSD.org>2004-12-12 00:32:51 +0000
committermarius <marius@FreeBSD.org>2004-12-12 00:32:51 +0000
commit13c1f64b09505c76d84ec51888879e28f33bb157 (patch)
tree30eb39c56ef50e7a2be288da55392b9d3c62d4e5 /sys/dev/hme
parent27e1f2c5b327a24e0580ff51352b25da1d4c5252 (diff)
downloadFreeBSD-src-13c1f64b09505c76d84ec51888879e28f33bb157.zip
FreeBSD-src-13c1f64b09505c76d84ec51888879e28f33bb157.tar.gz
Some changes related to reading the MAC-address from the VPD on systems
without Open Firmware: - The PCI data structure of some HME PROMs contains a non-zero interface revision in the class code. Thus remove the checks for matching class code and PCI data structure length and revsion. These were pretty much useless anyway as we only really need the pointer to the VPD which is located before the structure length and revision fields. - On Sun QFE (Quad FastEthernet) cards read the Nth MAC-address for the Nth HME controller instead of always the first one for all four HMEs. [1] - Improve the comment describing the used VPD format to better reflect reality. - Minor clean-up. Prodded by: joerg [1]
Diffstat (limited to 'sys/dev/hme')
-rw-r--r--sys/dev/hme/if_hme_pci.c37
1 files changed, 18 insertions, 19 deletions
diff --git a/sys/dev/hme/if_hme_pci.c b/sys/dev/hme/if_hme_pci.c
index 1095401..da5321c 100644
--- a/sys/dev/hme/if_hme_pci.c
+++ b/sys/dev/hme/if_hme_pci.c
@@ -157,22 +157,14 @@ hme_pci_attach(device_t dev)
PCI_PRODUCT_SUN_HMENETWORK >> 8
};
#define PROMDATA_PTR_VPD 0x08
-#define PROMDATA_DATA2 0x0a
- static const uint8_t promdat2[] = {
- 0x18, 0x00, /* structure length */
- 0x00, /* structure revision */
- 0x00, /* interface revision */
- PCIS_NETWORK_ETHERNET, /* subclass code */
- PCIC_NETWORK /* class code */
- };
-#define PCI_VPDRES_ISLARGE(x) ((x) & 0x80)
-#define PCI_VPDRES_LARGE_NAME(x) ((x) & 0x7f)
-#define PCI_VPDRES_TYPE_VPD 0x10 /* large */
struct pci_vpd {
uint8_t vpd_key0;
uint8_t vpd_key1;
uint8_t vpd_len;
} *vpd;
+#define PCI_VPDRES_ISLARGE(x) ((x) & 0x80)
+#define PCI_VPDRES_LARGE_NAME(x) ((x) & 0x7f)
+#define PCI_VPDRES_TYPE_VPD 0x10 /* large */
#endif
pci_enable_busmaster(dev);
@@ -299,7 +291,6 @@ hme_pci_attach(device_t dev)
/* Read PCI expansion PROM data. */
bus_space_read_region_1(romt, romh, dataoff, buf, sizeof(buf));
if (memcmp(buf, promdat, sizeof(promdat)) != 0 ||
- memcmp(buf + PROMDATA_DATA2, promdat2, sizeof(promdat2)) != 0 ||
(vpdoff = (buf[PROMDATA_PTR_VPD] |
(buf[PROMDATA_PTR_VPD + 1] << 8))) < 0x1c) {
device_printf(dev, "unexpected PCI expansion PROM data\n");
@@ -309,15 +300,22 @@ hme_pci_attach(device_t dev)
/*
* Read PCI VPD.
- * The VPD of HME is not in PCI 2.2 standard format. The length in
- * the resource header is in big endian, and resources are not
- * properly terminated (only one resource and no end tag).
+ * SUNW,hme cards have a single large resource VPD-R tag
+ * containing one NA. SUNW,qfe cards have four large resource
+ * VPD-R tags containing one NA each.
+ * The VPD used on both cards is not in PCI 2.2 standard format
+ * however. The length in the resource header is in big endian
+ * and the end tag is non-standard (0x79) and followed by an
+ * all-zero "checksum" byte. Sun calls this a "Fresh Choice
+ * Ethernet" VPD...
*/
- bus_space_read_region_1(romt, romh, vpdoff, buf, sizeof(buf));
+ bus_space_read_region_1(romt, romh,
+ vpdoff + slot * (3 + sizeof(struct pci_vpd) + ETHER_ADDR_LEN),
+ buf, sizeof(buf));
vpd = (void *)(buf + 3);
if (PCI_VPDRES_ISLARGE(buf[0]) == 0 ||
PCI_VPDRES_LARGE_NAME(buf[0]) != PCI_VPDRES_TYPE_VPD ||
- /* buf[1] != 0 || buf[2] != 9 || */ /*len*/
+ (buf[1] << 8 | buf[2]) != sizeof(struct pci_vpd) + ETHER_ADDR_LEN ||
vpd->vpd_key0 != 0x4e /* N */ ||
vpd->vpd_key1 != 0x41 /* A */ ||
vpd->vpd_len != ETHER_ADDR_LEN) {
@@ -325,12 +323,13 @@ hme_pci_attach(device_t dev)
error = ENXIO;
goto fail_rres;
}
- if (buf + 6 == NULL) {
+ if (buf + 3 + sizeof(struct pci_vpd) == NULL) {
device_printf(dev, "could not read network address\n");
error = ENXIO;
goto fail_rres;
}
- bcopy(buf + 6, sc->sc_arpcom.ac_enaddr, ETHER_ADDR_LEN);
+ bcopy(buf + 3 + sizeof(struct pci_vpd), sc->sc_arpcom.ac_enaddr,
+ ETHER_ADDR_LEN);
fail_rres:
bus_release_resource(ebus_dev, SYS_RES_MEMORY, ebus_rrid, ebus_rres);
OpenPOWER on IntegriCloud