diff options
author | mav <mav@FreeBSD.org> | 2013-04-11 06:34:41 +0000 |
---|---|---|
committer | mav <mav@FreeBSD.org> | 2013-04-11 06:34:41 +0000 |
commit | 4a4cddb38e7fbb7ca0a5a22b0698eb9d91d9775f (patch) | |
tree | 702325ceed8053f7e9a5ac20dfb65fcf43d67611 /sys/cam | |
parent | ea145a8678878b2fe9970cf8eb1b49a3fd807dec (diff) | |
download | FreeBSD-src-4a4cddb38e7fbb7ca0a5a22b0698eb9d91d9775f.zip FreeBSD-src-4a4cddb38e7fbb7ca0a5a22b0698eb9d91d9775f.tar.gz |
Do not sent 120 TEST UNIT READY requests on generic NOT READY statuses.
Some failing disks tend to return vendor-specific ASC/ASCQ codes with
NOT READY sense key. It caused extremely long recovery attempts, repeating
these 120 TURs (it takes at least 1 minute) for every I/O request.
Instead of that use default error handling, doing just few retries.
Reviewed by: ken, gibbs
MFC after: 1 month
Diffstat (limited to 'sys/cam')
-rw-r--r-- | sys/cam/scsi/scsi_all.c | 7 |
1 files changed, 2 insertions, 5 deletions
diff --git a/sys/cam/scsi/scsi_all.c b/sys/cam/scsi/scsi_all.c index 205cf22..b28c29d 100644 --- a/sys/cam/scsi/scsi_all.c +++ b/sys/cam/scsi/scsi_all.c @@ -699,10 +699,7 @@ const struct sense_key_table_entry sense_key_table[] = { { SSD_KEY_NO_SENSE, SS_NOP, "NO SENSE" }, { SSD_KEY_RECOVERED_ERROR, SS_NOP|SSQ_PRINT_SENSE, "RECOVERED ERROR" }, - { - SSD_KEY_NOT_READY, SS_TUR|SSQ_MANY|SSQ_DECREMENT_COUNT|EBUSY, - "NOT READY" - }, + { SSD_KEY_NOT_READY, SS_RDEF, "NOT READY" }, { SSD_KEY_MEDIUM_ERROR, SS_RDEF, "MEDIUM ERROR" }, { SSD_KEY_HARDWARE_ERROR, SS_RDEF, "HARDWARE FAILURE" }, { SSD_KEY_ILLEGAL_REQUEST, SS_FATAL|EINVAL, "ILLEGAL REQUEST" }, @@ -877,7 +874,7 @@ static struct asc_table_entry asc_table[] = { { SST(0x03, 0x02, SS_RDEF, "Excessive write errors") }, /* DTLPWROMAEBKVF */ - { SST(0x04, 0x00, SS_TUR | SSQ_MANY | SSQ_DECREMENT_COUNT | EIO, + { SST(0x04, 0x00, SS_RDEF, "Logical unit not ready, cause not reportable") }, /* DTLPWROMAEBKVF */ { SST(0x04, 0x01, SS_TUR | SSQ_MANY | SSQ_DECREMENT_COUNT | EBUSY, |