diff options
author | msmith <msmith@FreeBSD.org> | 2000-08-23 03:24:32 +0000 |
---|---|---|
committer | msmith <msmith@FreeBSD.org> | 2000-08-23 03:24:32 +0000 |
commit | 15a4808ee81d6861f2343ebde7c91dcdcd894d6f (patch) | |
tree | 012f204e9630a9a0ea1c750647f28404ec491861 /share | |
parent | 19a7cf4f83591586186dbc002cbfc9f1076b9dec (diff) | |
download | FreeBSD-src-15a4808ee81d6861f2343ebde7c91dcdcd894d6f.zip FreeBSD-src-15a4808ee81d6861f2343ebde7c91dcdcd894d6f.tar.gz |
Add a manpage for the new 'mly' driver.
Diffstat (limited to 'share')
-rw-r--r-- | share/man/man4/Makefile | 1 | ||||
-rw-r--r-- | share/man/man4/mly.4 | 273 |
2 files changed, 274 insertions, 0 deletions
diff --git a/share/man/man4/Makefile b/share/man/man4/Makefile index d2c113e..193563e 100644 --- a/share/man/man4/Makefile +++ b/share/man/man4/Makefile @@ -68,6 +68,7 @@ MAN4= adv.4 \ md.4 \ mem.4 \ mlx.4 \ + mly.4 \ mouse.4 \ mtio.4 \ natm.4 \ diff --git a/share/man/man4/mly.4 b/share/man/man4/mly.4 new file mode 100644 index 0000000..be968ab --- /dev/null +++ b/share/man/man4/mly.4 @@ -0,0 +1,273 @@ +.\" +.\" Copyright (c) 2000 Michael Smith +.\" Copyright (c) 2000 BSDi +.\" All rights reserved. +.\" +.\" Redistribution and use in source and binary forms, with or without +.\" modification, are permitted provided that the following conditions +.\" are met: +.\" 1. Redistributions of source code must retain the above copyright +.\" notice, this list of conditions and the following disclaimer. +.\" 2. The name of the author may not be used to endorse or promote products +.\" derived from this software without specific prior written permission +.\" +.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR +.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES +.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. +.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, +.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT +.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, +.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY +.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT +.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF +.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. +.\" +.\" $FreeBSD$ +.\" +.Dd August 22, 2000 +.Dt MLY 4 +.Os +.Sh NAME +.Nm mly +.Nd Mylex AcceleRAID/eXtremeRAID family driver +.Sh SYNOPSIS +.Cd device pci +.Cd device mly +.Cd device scbus +.Cd device da +.Sh DESCRIPTION +The +.Nm +driver provides support for Mylex AcceleRAID and eXtremeRAID-family +PCI to SCSI RAID controllers with version 6.00 and later +firmware. Supported controllers include: +.Bl -bullet +.It +AcceleRAID 160 +.It +AcceleRAID 170 +.It +AcceleRAID 352 +.It +eXtremeRAID 2000 +.It +eXtremeRAID 3000 +.El +.Pp +Compatible Mylex controllers not listed should work, but have not been +verified. +.Pp +Logical devices (array drives) attached to the controller are presented +to the SCSI subsystem as though they were direct-access devices on a +virtual SCSI bus. Physical devices which are not claimed by a logical +device are presented on SCSI channels which match the physical channels +on the controller. +.Sh DIAGNOSTICS +Controller initialisation phase: +.Bl -diag +.It "mly%d: controller initialisation started" +.It "mly%d: initialisation complete" +.El +.Pp +The controller firmware has started initialisation. Normally this +process is performed by the controller BIOS, but the driver may need +to do this in cases where the BIOS has failed, or is not compatible +(eg. on non-x86 systems). +.Bl -diag +.It "mly%d: drive spinup in progress" +.El +.Pp +Drive startup is in progress; this may take several minutes. +.Bl -diag +.It "mly%d: mirror race recovery failed, one or more drives offline" +.It "mly%d: mirror race recovery in progress" +.It "mly%d: mirror race recovery on a critical drive" +.El +.Pp +These error codes are undocumented. +.Bl -diag +.It "mly%d: FATAL MEMORY PARITY ERROR" +.El +.Pp +Firmware detected a fatal memory error; the driver will not attempt to +attach to this controller. +.Bl -diag +.It "mly%d: unknown initialisation code %x" +.El +.Pp +An unknown error occurred during initialisation; it will be ignored. +.Pp +Driver initialisation/shutdown phase: +.Bl -diag +.It "mly%d: can't enable busmaster feature" +.It "mly%d: memory window not available" +.It "mly%d: can't allocate register window" +.It "mly%d: can't allocate interrupt" +.It "mly%d: can't set up interrupt" +.El +.Pp +The system's PCI BIOS has not correctly configured the controller's +PCI interface; initialisation has failed and the driver will not +attach to this controller. +.Bl -diag +.It "mly%d: can't allocate parent DMA tag" +.It "mly%d: can't allocate buffer DMA tag" +.It "mly%d: can't allocate command packet DMA tag" +.It "mly%d: can't allocate scatter/gather DMA tag" +.It "mly%d: can't allocate s/g table" +.It "mly%d: can't allocate memory mailbox DMA tag" +.It "mly%d: can't allocate memory mailbox" +.El +.Pp +A resource allocation error occurred while initialising the driver; +initialisation has failed and the driver will not attach to this +controller. +.Bl -diag +.It "mly%d: BTL rescan result corrupted" +.El +.Pp +The results of a scan for an attached device were corrupted. One or +more devices may not be correctly reported. +.Bl -diag +.It "mly%d: flushing cache..." +.El +.Pp +The controller cache is being flushed prior to detach or shutdown. +.Pp +Operational diagnostics: +.Bl -diag +.It "mly%d: physical device %d:%d online" +.It "mly%d: physical device %d:%d standby" +.It "mly%d: physical device %d:%d automatic rebuild started" +.It "mly%d: physical device %d:%d manual rebuild started" +.It "mly%d: physical device %d:%d rebuild completed" +.It "mly%d: physical device %d:%d rebuild cancelled" +.It "mly%d: physical device %d:%d rebuild failed for unknown reasons" +.It "mly%d: physical device %d:%d rebuild failed due to new physical device" +.It "mly%d: physical device %d:%d rebuild failed due to logical drive failure" +.It "mly%d: physical device %d:%d found" +.It "mly%d: physical device %d:%d gone" +.It "mly%d: physical device %d:%d unconfigured" +.It "mly%d: physical device %d:%d expand capacity started" +.It "mly%d: physical device %d:%d expand capacity completed" +.It "mly%d: physical device %d:%d expand capacity failed" +.It "mly%d: physical device %d:%d parity error" +.It "mly%d: physical device %d:%d soft error" +.It "mly%d: physical device %d:%d miscellaneous error" +.It "mly%d: physical device %d:%d reset" +.It "mly%d: physical device %d:%d active spare found" +.It "mly%d: physical device %d:%d warm spare found" +.It "mly%d: physical device %d:%d initialization started" +.It "mly%d: physical device %d:%d initialization completed" +.It "mly%d: physical device %d:%d initialization failed" +.It "mly%d: physical device %d:%d initialization cancelled" +.It "mly%d: physical device %d:%d write recovery failed" +.It "mly%d: physical device %d:%d scsi bus reset failed" +.It "mly%d: physical device %d:%d double check condition" +.It "mly%d: physical device %d:%d device cannot be accessed" +.It "mly%d: physical device %d:%d gross error on scsi processor" +.It "mly%d: physical device %d:%d bad tag from device" +.It "mly%d: physical device %d:%d command timeout" +.It "mly%d: physical device %d:%d system reset" +.It "mly%d: physical device %d:%d busy status or parity error" +.It "mly%d: physical device %d:%d host set device to failed state" +.It "mly%d: physical device %d:%d selection timeout" +.It "mly%d: physical device %d:%d scsi bus phase error" +.It "mly%d: physical device %d:%d device returned unknown status" +.It "mly%d: physical device %d:%d device not ready" +.It "mly%d: physical device %d:%d device not found at startup" +.It "mly%d: physical device %d:%d COD write operation failed" +.It "mly%d: physical device %d:%d BDT write operation failed" +.It "mly%d: physical device %d:%d missing at startup" +.It "mly%d: physical device %d:%d start rebuild failed due to physical drive too small" +.It "mly%d: physical device %d:%d sense data received" +.It "mly%d: sense key %d asc %02x ascq %02x" +.It "mly%d: info %4D csi %4D" +.It "mly%d: physical device %d:%d offline" +.It "mly%d: sense key %d asc %02x ascq %02x" +.It "mly%d: info %4D csi %4D" +.El +.Pp +The reported event refers to the physical device at the given channel:target +address. +.Bl -diag +.It "mly%d: logical device %d (%s) consistency check started" +.It "mly%d: logical device %d (%s) consistency check completed" +.It "mly%d: logical device %d (%s) consistency check cancelled" +.It "mly%d: logical device %d (%s) consistency check completed with errors" +.It "mly%d: logical device %d (%s) consistency check failed due to logical drive failure" +.It "mly%d: logical device %d (%s) consistency check failed due to physical device failure" +.It "mly%d: logical device %d (%s) automatic rebuild started" +.It "mly%d: logical device %d (%s) manual rebuild started" +.It "mly%d: logical device %d (%s) rebuild completed" +.It "mly%d: logical device %d (%s) rebuild cancelled" +.It "mly%d: logical device %d (%s) rebuild failed for unknown reasons" +.It "mly%d: logical device %d (%s) rebuild failed due to new physical device" +.It "mly%d: logical device %d (%s) rebuild failed due to logical drive failure" +.It "mly%d: logical device %d (%s) offline" +.It "mly%d: logical device %d (%s) critical" +.It "mly%d: logical device %d (%s) online" +.It "mly%d: logical device %d (%s) initialization started" +.It "mly%d: logical device %d (%s) initialization completed" +.It "mly%d: logical device %d (%s) initialization cancelled" +.It "mly%d: logical device %d (%s) initialization failed" +.It "mly%d: logical device %d (%s) found" +.It "mly%d: logical device %d (%s) gone" +.It "mly%d: logical device %d (%s) expand capacity started" +.It "mly%d: logical device %d (%s) expand capacity completed" +.It "mly%d: logical device %d (%s) expand capacity failed" +.It "mly%d: logical device %d (%s) bad block found" +.It "mly%d: logical device %d (%s) size changed" +.It "mly%d: logical device %d (%s) type changed" +.It "mly%d: logical device %d (%s) bad data block found" +.It "mly%d: logical device %d (%s) read of data block in bdt" +.It "mly%d: logical device %d (%s) write back data for disk block lost" +.El +.Pp +The event report will include the name of the SCSI device which has +attached to the device if possible. +.Bl -diag +.It "mly%d: enclosure %d fan %d failed" +.It "mly%d: enclosure %d fan %d ok" +.It "mly%d: enclosure %d fan %d not present" +.It "mly%d: enclosure %d power supply %d failed" +.It "mly%d: enclosure %d power supply %d ok" +.It "mly%d: enclosure %d power supply %d not present" +.It "mly%d: enclosure %d temperature sensor %d failed" +.It "mly%d: enclosure %d temperature sensor %d critical" +.It "mly%d: enclosure %d temperature sensor %d ok" +.It "mly%d: enclosure %d temperature sensor %d not present" +.It "mly%d: enclosure %d unit %d access critical" +.It "mly%d: enclosure %d unit %d access ok" +.It "mly%d: enclosure %d unit %d access offline" +.El +.Pp +These events refer to external enclosures by number. The driver +does not attempt to name the enclosures. +.Bl -diag +.It "mly%d: controller cache write back error" +.It "mly%d: controller battery backup unit found" +.It "mly%d: controller battery backup unit charge level low" +.It "mly%d: controller battery backup unit charge level ok" +.It "mly%d: controller installation aborted" +.It "mly%d: controller mirror race recovery in progress" +.It "mly%d: controller mirror race on critical drive" +.It "mly%d: controller memory soft ecc error" +.It "mly%d: controller memory hard ecc error" +.It "mly%d: controller battery backup unit failed" +.El +.Pp +These events report controller status changes. +.Sh BUGS +The driver does not yet provide an external management interface. +.Pp +Enclosures are not named or otherwise identified in event messages. +.Sh AUTHORS +The mly driver was written by +.An Michael Smith +.Aq msmith@FreeBSD.org . +.Pp +This manual page was written by +.An Michael Smith +.Aq msmith@FreeBSD.org . + |