After much delay and anticipation, welcome RAIDFrame into the FreeBSD
world. This should be considered highly experimental. Approved-by: re
Diffstat (limited to 'share/man/man4/raid.4')
-rw-r--r--share/man/man4/raid.4342
1 files changed, 342 insertions, 0 deletions
diff --git a/share/man/man4/raid.4 b/share/man/man4/raid.4
new file mode 100644
index 0000000..54c8b77
--- /dev/null
+++ b/share/man/man4/raid.4
@@ -0,0 +1,342 @@
+.\" $FreeBSD$
+.\" $NetBSD: raid.4,v 1.16 2000/11/02 03:34:08 oster Exp $
+.\"
+.\" Copyright (c) 1998 The NetBSD Foundation, Inc.
+.\" All rights reserved.
+.\"
+.\" This code is derived from software contributed to The NetBSD Foundation
+.\" by Greg Oster
+.\"
+.\" Redistribution and use in source and binary forms, with or without
+.\" modification, are permitted provided that the following conditions
+.\" are met:
+.\" 1. Redistributions of source code must retain the above copyright
+.\" notice, this list of conditions and the following disclaimer.
+.\" 2. Redistributions in binary form must reproduce the above copyright
+.\" notice, this list of conditions and the following disclaimer in the
+.\" documentation and/or other materials provided with the distribution.
+.\" 3. All advertising materials mentioning features or use of this software
+.\" must display the following acknowledgement:
+.\" This product includes software developed by the NetBSD
+.\" Foundation, Inc. and its contributors.
+.\" 4. Neither the name of The NetBSD Foundation nor the names of its
+.\" contributors may be used to endorse or promote products derived
+.\" from this software without specific prior written permission.
+.\"
+.\" THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS
+.\" ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
+.\" TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
+.\" PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE FOUNDATION OR CONTRIBUTORS
+.\" BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
+.\" CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
+.\" SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
+.\" INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
+.\" CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
+.\" ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
+.\" POSSIBILITY OF SUCH DAMAGE.
+.\"
+.\"
+.\" Copyright (c) 1995 Carnegie-Mellon University.
+.\" All rights reserved.
+.\"
+.\" Author: Mark Holland
+.\"
+.\" Permission to use, copy, modify and distribute this software and
+.\" its documentation is hereby granted, provided that both the copyright
+.\" notice and this permission notice appear in all copies of the
+.\" software, derivative works or modified versions, and any portions
+.\" thereof, and that both notices appear in supporting documentation.
+.\"
+.\" CARNEGIE MELLON ALLOWS FREE USE OF THIS SOFTWARE IN ITS "AS IS"
+.\" CONDITION. CARNEGIE MELLON DISCLAIMS ANY LIABILITY OF ANY KIND
+.\" FOR ANY DAMAGES WHATSOEVER RESULTING FROM THE USE OF THIS SOFTWARE.
+.\"
+.\" Carnegie Mellon requests users of this software to return to
+.\"
+.\" Software Distribution Coordinator or Software.Distribution@CS.CMU.EDU
+.\" School of Computer Science
+.\" Carnegie Mellon University
+.\" Pittsburgh PA 15213-3890
+.\"
+.\" any improvements or extensions that they make and grant Carnegie the
+.\" rights to redistribute these changes.
+.\"
+.Dd October 20, 2002
+.Dt RAID 4
+.Os
+.Sh NAME
+.Nm raid
+.Nd RAIDframe disk driver
+.Sh SYNOPSIS
+.Cd device raidframe
+.Sh DESCRIPTION
+The
+.Nm
+driver provides RAID 0, 1, 4, and 5 (and more!) capabilities to
+.Fx .
+This
+document assumes that the reader has at least some familiarity with RAID
+and RAID concepts. The reader is also assumed to know how to configure
+disks and pseudo-devices into kernels, how to generate kernels, and how
+to partition disks.
+.Pp
+RAIDframe provides a number of different RAID levels including:
+.Bl -tag -width indent
+.It RAID 0
+provides simple data striping across the components.
+.It RAID 1
+provides mirroring.
+.It RAID 4
+provides data striping across the components, with parity
+stored on a dedicated drive (in this case, the last component).
+.It RAID 5
+provides data striping across the components, with parity
+distributed across all the components.
+.El
+.Pp
+There are a wide variety of other RAID levels supported by RAIDframe,
+including Even-Odd parity, RAID level 5 with rotated sparing, Chained
+declustering, and Interleaved declustering. The reader is referred
+to the RAIDframe documentation mentioned in the
+.Sx HISTORY
+section for more detail on these various RAID configurations.
+.Pp
+Depending on the parity level configured, the device driver can
+support the failure of component drives. The number of failures
+allowed depends on the parity level selected. If the driver is able
+to handle drive failures, and a drive does fail, then the system is
+operating in "degraded mode". In this mode, all missing data must be
+reconstructed from the data and parity present on the other
+components. This results in much slower data accesses, but
+does mean that a failure need not bring the system to a complete halt.
+.Pp
+The RAID driver supports and enforces the use of
+.Sq component labels .
+A
+.Sq component label
+contains important information about the component, including a
+user-specified serial number, the row and column of that component in
+the RAID set, and whether the data (and parity) on the component is
+.Sq clean .
+If the driver determines that the labels are very inconsistent with
+respect to each other (e.g. two or more serial numbers do not match)
+or that the component label is not consistent with it's assigned place
+in the set (e.g. the component label claims the component should be
+the 3rd one a 6-disk set, but the RAID set has it as the 3rd component
+in a 5-disk set) then the device will fail to configure. If the
+driver determines that exactly one component label seems to be
+incorrect, and the RAID set is being configured as a set that supports
+a single failure, then the RAID set will be allowed to configure, but
+the incorrectly labeled component will be marked as
+.Sq failed ,
+and the RAID set will begin operation in degraded mode.
+If all of the components are consistent among themselves, the RAID set
+will configure normally.
+.Pp
+Component labels are also used to support the auto-detection and
+auto-configuration of RAID sets. A RAID set can be flagged as
+auto-configurable, in which case it will be configured automatically
+during the kernel boot process. RAID filesystems which are
+automatically configured are also eligible to be the root filesystem.
+There is currently only limited support (alpha and pmax architectures)
+for booting a kernel directly from a RAID 1 set, and no support for
+booting from any other RAID sets. To use a RAID set as the root
+filesystem, a kernel is usually obtained from a small non-RAID
+partition, after which any auto-configuring RAID set can be used for the
+root filesystem. See
+.Xr raidctl 8
+for more information on auto-configuration of RAID sets.
+.Pp
+The driver supports
+.Sq hot spares ,
+disks which are on-line, but are not
+actively used in an existing filesystem. Should a disk fail, the
+driver is capable of reconstructing the failed disk onto a hot spare
+or back onto a replacement drive.
+If the components are hot swapable, the failed disk can then be
+removed, a new disk put in its place, and a copyback operation
+performed. The copyback operation, as its name indicates, will copy
+the reconstructed data from the hot spare to the previously failed
+(and now replaced) disk. Hot spares can also be hot-added using
+.Xr raidctl 8 .
+.Pp
+If a component cannot be detected when the RAID device is configured,
+that component will be simply marked as 'failed'.
+.Pp
+The user-land utility for doing all
+.Nm
+configuration and other operations
+is
+.Xr raidctl 8 .
+Most importantly,
+.Xr raidctl 8
+must be used with the
+.Fl i
+option to initialize all RAID sets. In particular, this
+initialization includes re-building the parity data. This rebuilding
+of parity data is also required when either a) a new RAID device is
+brought up for the first time or b) after an un-clean shutdown of a
+RAID device. By using the
+.Fl P
+option to
+.Xr raidctl 8 ,
+and performing this on-demand recomputation of all parity
+before doing a
+.Xr fsck 8
+or a
+.Xr newfs 8 ,
+filesystem integrity and parity integrity can be ensured. It bears
+repeating again that parity recomputation is
+.Ar required
+before any filesystems are created or used on the RAID device. If the
+parity is not correct, then missing data cannot be correctly recovered.
+.Pp
+RAID levels may be combined in a hierarchical fashion. For example, a RAID 0
+device can be constructed out of a number of RAID 5 devices (which, in turn,
+may be constructed out of the physical disks, or of other RAID devices).
+.Pp
+It is important that drives be hard-coded at their respective
+addresses (i.e. not left free-floating, where a drive with SCSI ID of
+4 can end up as /dev/da0c) for well-behaved functioning of the RAID
+device. This is true for all types of drives, including IDE, SCSI,
+etc. For IDE drivers, use the option ATAPI_STATIC_ID in your kernel
+config file. For SCSI, you should 'wire down' the devices according to
+their ID. See
+.Xr cam 4
+for examples of this.
+The rationale for fixing the device addresses
+is as follows: Consider a system with three SCSI drives at SCSI ID's
+4, 5, and 6, and which map to components /dev/da0e, /dev/da1e, and
+/dev/da2e of a RAID 5 set. If the drive with SCSI ID 5 fails, and the
+system reboots, the old /dev/da2e will show up as /dev/da1e. The RAID
+driver is able to detect that component positions have changed, and
+will not allow normal configuration. If the device addresses are hard
+coded, however, the RAID driver would detect that the middle component
+is unavailable, and bring the RAID 5 set up in degraded mode. Note
+that the auto-detection and auto-configuration code does not care
+about where the components live. The auto-configuration code will
+correctly configure a device even after any number of the components
+have been re-arranged.
+.Pp
+The first step to using the
+.Nm
+driver is to ensure that it is suitably configured in the kernel. This is
+done by adding a line similar to:
+.Bd -unfilled -offset indent
+pseudo-device raidframe # RAIDframe disk device
+.Ed
+.Pp
+to the kernel configuration file. No count argument is required as the
+driver will automatically create and configure new device units as needed.
+To turn on component auto-detection and auto-configuration of RAID
+sets, simply add:
+.Bd -unfilled -offset indent
+options RAID_AUTOCONFIG
+.Ed
+.Pp
+to the kernel configuration file.
+.Pp
+All component partitions must be of the type
+.Dv FS_BSDFFS
+(e.g. 4.2BSD) or
+.Dv FS_RAID .
+The use of the latter is strongly encouraged, and is required if
+auto-configuration of the RAID set is desired. Since RAIDframe leaves
+room for disklabels, RAID components can be simply raw disks, or
+partitions which use an entire disk.
+.Pp
+A more detailed treatment of actually using a
+.Nm
+device is found in
+.Xr raidctl 8 .
+It is highly recommended that the steps to reconstruct, copyback, and
+re-compute parity are well understood by the system administrator(s)
+.Ar before
+a component failure. Doing the wrong thing when a component fails may
+result in data loss.
+.Pp
+.Sh WARNINGS
+Certain RAID levels (1, 4, 5, 6, and others) can protect against some
+data loss due to component failure. However the loss of two
+components of a RAID 4 or 5 system, or the loss of a single component
+of a RAID 0 system, will result in the entire filesystems on that RAID
+device being lost.
+RAID is
+.Ar NOT
+a substitute for good backup practices.
+.Pp
+Recomputation of parity
+.Ar MUST
+be performed whenever there is a chance that it may have been
+compromised. This includes after system crashes, or before a RAID
+device has been used for the first time. Failure to keep parity
+correct will be catastrophic should a component ever fail -- it is
+better to use RAID 0 and get the additional space and speed, than it
+is to use parity, but not keep the parity correct. At least with RAID
+0 there is no perception of increased data security.
+.Pp
+.Sh FILES
+.Bl -tag -width /dev/XXrXraidX -compact
+.It Pa /dev/raid*
+.Nm
+device special files.
+.El
+.Pp
+.Sh SEE ALSO
+.Xr raidctl 8 ,
+.Xr config 8 ,
+.Xr fsck 8 ,
+.Xr mount 8 ,
+.Xr newfs 8 ,
+.Sh HISTORY
+The
+.Nm
+driver in
+.Fx
+is a port of RAIDframe, a framework for rapid prototyping of RAID
+structures developed by the folks at the Parallel Data Laboratory at
+Carnegie Mellon University (CMU). RAIDframe, as originally distributed
+by CMU, provides a RAID simulator for a number of different
+architectures, and a user-level device driver and a kernel device
+driver for Digital Unix. The
+.Nm
+driver is a kernelized version of RAIDframe v1.1, based on the
+.Nx
+port of RAIDframe by Greg Oster.
+.Pp
+A more complete description of the internals and functionality of
+RAIDframe is found in the paper "RAIDframe: A Rapid Prototyping Tool
+for RAID Systems", by William V. Courtright II, Garth Gibson, Mark
+Holland, LeAnn Neal Reilly, and Jim Zelenka, and published by the
+Parallel Data Laboratory of Carnegie Mellon University.
+The
+.Nm
+driver first appeared in
+.Fx 4.4 .
+.Sh COPYRIGHT
+.Bd -unfilled
+The RAIDframe Copyright is as follows:
+
+Copyright (c) 1994-1996 Carnegie-Mellon University.
+All rights reserved.
+
+Permission to use, copy, modify and distribute this software and
+its documentation is hereby granted, provided that both the copyright
+notice and this permission notice appear in all copies of the
+software, derivative works or modified versions, and any portions
+thereof, and that both notices appear in supporting documentation.
+
+CARNEGIE MELLON ALLOWS FREE USE OF THIS SOFTWARE IN ITS "AS IS"
+CONDITION. CARNEGIE MELLON DISCLAIMS ANY LIABILITY OF ANY KIND
+FOR ANY DAMAGES WHATSOEVER RESULTING FROM THE USE OF THIS SOFTWARE.
+
+Carnegie Mellon requests users of this software to return to
+
+ Software Distribution Coordinator or Software.Distribution@CS.CMU.EDU
+ School of Computer Science
+ Carnegie Mellon University
+ Pittsburgh PA 15213-3890
+
+any improvements or extensions that they make and grant Carnegie the
+rights to redistribute these changes.
+.Ed
OpenPOWER on IntegriCloud